Analytical Instrument Documents

Since 1949, the JEOL legacy has been one of outstanding innovation in developing instruments used to advance scientific research and technology. JEOL has over 60 years of expertise in the field of electron microscopy, more than 50 years in mass spectrometry. In this applications note, we performed an analysis of a Gold Star Mothers Postage Stamp by using three JEOL instruments. We used the JSM-IT300LV which the latest addition to JEOL‘s popular series of analytical low vacuum SEM, , the JMS-T100LP “AccuTOF- DART” the first commercially available ambient ionization mass spectrometer, and the JMS-S3000 “SpiralTOF” which has highest mass-resolution and mass accuracy of all commercially available MALDI-TOFMS systems. We can therefore correlate analyses from various analytical techniques on the same sample.

MALDI imaging is a state-of-art mass spectrometry technique that allows for the visualization of chemical distributions on the surfaces of biological and material samples. This analytical technique can provide the chemical distribution on the surface as an image that is mapped using the intensity of the observed ions. The image contains individual MALDI mass spectra at each pixel. Therefore, it is possible to simultaneously carry out high-mass-resolution qualitative analysis and chemical distribution analysis. The JMS-S3000 SpiralTOF (Figure 1) has a unique 17m fl ight path that offers the highest mass resolution and mass accuracy MALDI-TOF MS system. In this work, we demonstrated the MALDI imaging measurement for the fi ngerprints of a smoker and a non-smoker by using the JEOL SpiralTOF system. Additionally, we looked at the smoker’s fi ngerprint using the JEOL JSM-7800F thermal fi eld emission scanning electron microscope (FE-SEM) shown in Figure 2.

Recently, matrix assisted laser desorption/ionization (MALDI) imaging techniques have been developed for biological sciences to evaluate and understand the distribution of various chemicals on biological surfaces. In particular, this technique provides useful visual information about the locations of specific chemicals on surfaces. In this work, we explored the use of laser desorption/ionization (LDI) imaging for forensically applicable samples such as a handwriting sample with a ballpoint ink. These measurements were done using a spiral-trajectory ion optics time-of-flight mass spectrometer (SpiralTOF-MS). This TOF system has a 17m flight path that provides high resolution capabilities even down into the lower m/z region. Additionally, we looked at the SEM/EDS imaging using the JEOL JSM-6510LV scanning electron microscope.

Industrial materials are often evaluated by surface analysis instruments that provide information on surface elements, bonding states, and functional groups. However, there are limited options for surface analysis techniques that provide molecular weight and molecular structure information for organic compounds present on surfaces. Matrix Assisted Laser Desorption Ionization - Time of Flight Mass Spectrometry (MALDI-TOFMS) is a soft ionization technique that can be used to analyze surfaces in order to estimate elemental compositions with accurate mass measurements, obtain structural information by using MS/MS, and map surface compounds by using MS imaging. MALDI-TOFMS uses a high voltage on the target plate to accelerate the ions into the TOFMS analyzer. Therefore, the target plates are conductive and are typically made of stainless steel. MALDI imaging mass spectrometry is widely used for analyzing organic substances on frozen tissue sections. In this case, a frozen tissue section with a thickness of about 10 μm is placed on a conductive glass slide coated with an indium tin oxide (ITO) film. However, for the analysis of industrial products, the target organic compounds are on nonconductive substrates such as resins with millimeter thicknesses. MALDI-TOFMS surface measurements using nonconductive substrates lead to a reduction in mass resolution and a significant decrease in ion intensity due to surface charging. This problem can be solved by pretreating the surface with gold vapor deposition in order to change it from nonconductive to conductive. This method was previously shown to work well in MSTips No. 204 in which the gold vapor deposition method was applied to the MALDI-MS imaging analysis of inks on paper. In this report, we used gold vapor deposition to look at samples on the surface of a 1 mm thick acrylic plate.

Biological markers (biomarkers) are compounds such as terpanes, steranes, and steroids that are derived from organisms present in the original biomass from which organic-rich sediments and oils were formed. These compounds can be measured in both oils and source rock bitumens, and they can be used to establish a correlation between an oil sample and the original petroleum source rock. Combined gas chromatography / mass spectrometry (GC/MS) can be used to analyze for biomarkers in oil samples. However, there are numerous interferences present that have the same integer mass as biomarkers, but different elemental compositions. Because these isobaric compounds have different exact masses than the biomarkers, the interferences can be separated by high-resolution mass spectrometry. Some examples of compounds that interfere with the detection of biomarkers are given in Table I.

Most familiar applications of high resolution mass spectrometry relate to exact mass measurements for elemental composition determination of compounds such as natural products, environmental contaminants, petrochemicals and synthetic organic compounds. However, high resolution can also be useful at the very low end of the mass scale for monitoring gases and isotopes. The GCmate has a mass range that extends as low as m/z 1 and as high as m/z 3000 (at reduced accelerating voltage) and is capable of a resolving power up to 5,000. This is more than sufficient for analyzing low-mass species such as CO and N2 as well as H+, D+, H2+, HD+ etc. The example shown above was obtained by monitoring H2+ (m/z 2.01565) and D+ (m/z 2.0141) from a mixture of D2O and H2O at a resolving power of 3400. The difference in mass between these two species is only 0.00155 u.

A few needles from the holiday tree in the lobby of our Peabody office were extracted with dichloromethane and analyzed with the JEOL GCmate GC/MS system. Components were identified by a library search of the mass spectra. The fragrance comes from a complex mixture of terpenes such as alpha-pinene (familiar pine aroma) and limonene (citrus aroma) and other compounds, such as maltol (fresh-baked bread aroma).

The GCmate and LCmate benchtop mass spectrometers can be fitted with an optional fast atom bombardment (FAB) ion source that provides a means for rapid and convenient analysis of polar or thermally labile molecules. The FAB source can be operated in positive and negative-ion mode, and it can be used for high-resolution or MS/MS measurements (with the linked scan MS/MS option). The LCmate can be fitted with an optional frit-FAB LC/MS interface, and an auto-probe has also been developed that can allow unattended analysis of up to 40 direct-probe FAB samples at a time. Some examples of FAB analysis with GCmate are shown here.

A high chemical background or the continuous introduction of a reference compound can make it difficult to locate and identify trace components in a total ion current chromatogram in a GC/MS or LC/MS experiment. The Shrader System for Windows™ software1 available with the JEOL GCmate, LCmate, and RSVP mass spectrometers provides a solution to this problem based on the Component Detection Algorithm (CODA), developed by Windig et. al.2 The CODA algorithm identifies significant peaks by comparing a smoothed, mean-subtracted reconstructed ion chromatogram (RIC) with the original RIC.

Solid-phase microextraction (SPME) is a convenient sample preparation method for extracting organic compounds from aqueous samples. The combination of SPME with gas chromatography and high-resolution mass spectrometry provides powerful capabilities for the analysis of alcoholic beverages. Two samples of Scotch whiskey and one tequila sample were sampled by using solid-phase microextraction for analysis by high-resolution GC/MS. Sample 1 was a blended 12-year old light Scotch whiskey, while sample 2 was a 12-year old single-malt light Scotch whiskey. The tequila sample was a popular brand that is widely sold in the USA. Compounds were extracted and identified by GC/MS with library search. Exact mass measurements provided elemental compositions for molecular ions and fragment ions.

rss

Other Resources

Walkup NMR
  • See how the Delta NMR software allows users to just "walk up" and start NMR experiments
  • Mass Spec Reference Data
  • View our page of useful molecular references for Mass Spec
  • Tutorials (Mass Spec)
  • Documents on the basics of mass spectrometry
  • Delta NMR software Tutorials
  • Videos on how to use the Delta NMR software
  • No-D NMR
  • Description of No-D NMR and how it can be used to eliminate the need for deuterated solvents
  • Non Uniform Sampling (NUS)
  • Description of how NUS is used to greatly reduce the time needed for running NMR experiments
  • NMR Basics
  • Overview of the Basics of NMR Theory
  • NMR Magnet Destruction
  • See our presentation of the slicing open of a JEOL Delta-GSX 270 MHz NMR Magnet
  • NMR Training
    Basic Operations and System Management for JEOL NMR Users
    Mass Spec Training
    Learn more about spectrometer operation and maintenance, data collection and processing, and advanced MS software operation.
    JEOLink NMR Newsletter
    We publish and send out this NMR newsletter to our customers. They can also be viewed here.
    Mass Media Newsletter
    We publish and send out this Mass Spec newsletter to our customers. They can also be viewed here.