Analytical Instrument Documents

High-resolution mass spectrometry (HRMS) continues to play an important role in the compositional characterization of larger organic molecules. In the field of polymer characterization, however, the application of HRMS has made only slow progress because of lower compatibility between matrix-assisted laser desorption/ionization (MALDI) and ultrahigh-resolution Fourier transform ion cyclotron resonance mass spectrometry (FT-ICRMS). In this study, a newly developed type of MALDI high-resolution time-of-flight mass spectrometry (TOFMS) with a spiral ion trajectory (MALDI spiral-TOFMS) was applied to the structural and compositional characterization of polymers. To create a graphical distribution of polymer components on a two-dimensional plot converted from complex mass spectra, we adopted a slightly modified Kendrick mass defect (KMD) analysis based on accurate masses determined using spiral-TOFMS. By setting the Kendrick mass scale based on the mass of the repeating units of a given polymer, components with common repeat units lined up in the horizontal direction on the KMD plot, whereas those components with different structures were shifted vertically. This combination of MALDI spiral-TOFMS measurement and KMD analysis enabled the successful discrimination of the polymer components in a blend of poly(alkylene oxide)s, the compositional analysis of poly(ethylene oxide)/poly(propylene oxide) block copolymers, and profiling of the end-group distribution of poly(ε- caprolactone)s synthesized under different conditions.

Traceability and authenticity of olive oils in Croatia were probed by a versatile analytical approach using spiral MALDI-TOF MS system for the triacylglycerol (TAG) analysis. Molecular ion patterns were shown to represent specific data for statistical analysis, in which differences of cultivar regions of Croatian coast were recognized. This pilot project allows indications to be followed in high throughput procedures with high number of samples to get statistically relevant data for discrimination of olive oils from different geographic sites. Additionally, the fragmentation in the TOF/TOF MS provided distinct highly valuable data for assignment of acyl residues. In this way molecular species with different fatty acid substituents can be clearly assigned and possible isomeric mixtures identified.

The structural characterization of copolymers by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) remains a challenging task, since their random comonomer distribution creates very complicated mass spectra. In this study, a high-resolution TOF mass spectrometer with a spiral ion trajectory was applied to the structural and compositional characterization of free radical copolymerized poly(methyl methacrylate-co-tert-butyl methacrylate), poly(MMA-co-tBMA)s in ethyl lactate acting as a chain transfer agent. Virtually complete peak assignments of the isobaric components within the poly(MMA-co-tBMA)s served to identify the end-group combinations and copolymer compositions of individual copolymer components, allowing the distributions of comonomer compositions and six types of end-group combinations to be evaluated.

Last Updated: September 2013

rss

Other Resources

Walkup NMR
  • See how the Delta NMR software allows users to just "walk up" and start NMR experiments
  • Mass Spec Reference Data
  • View our page of useful molecular references for Mass Spec
  • Tutorials (Mass Spec)
  • Documents on the basics of mass spectrometry
  • Delta NMR software Tutorials
  • Videos on how to use the Delta NMR software
  • No-D NMR
  • Description of No-D NMR and how it can be used to eliminate the need for deuterated solvents
  • Non Uniform Sampling (NUS)
  • Description of how NUS is used to greatly reduce the time needed for running NMR experiments
  • NMR Basics
  • Overview of the Basics of NMR Theory
  • NMR Magnet Destruction
  • See our presentation of the slicing open of a JEOL Delta-GSX 270 MHz NMR Magnet
  • NMR Training
    Basic Operations and System Management for JEOL NMR Users
    Mass Spec Training
    Learn more about spectrometer operation and maintenance, data collection and processing, and advanced MS software operation.
    JEOLink NMR Newsletter
    We publish and send out this NMR newsletter to our customers. They can also be viewed here.
    Mass Media Newsletter
    We publish and send out this Mass Spec newsletter to our customers. They can also be viewed here.
    © Copyright 2024 by JEOL USA, Inc.
    Terms of Use
    |
    Privacy Policy
    |
    Cookie Preferences