Analytical Instrument Documents

Smokeless powders are often used in improvised explosive devices. The formulations for smokeless powders vary between manufacturers and between brands from a given manufacturer; ingredients include energetics, stabilizers, plasticizers and deterrents. Both chemical composition and morphology are important in characterizing smokeless powders. Chemical analysis of smokeless powders can provide valuable forensic evidence. Observation with the SEM can reveal morphological information to help with identification. Here we show how SEM-EDS analysis can be used to identify inorganic components, and how the AccuTOF-DART mass spectrometer can rapidly identify the organic components and provide a chemical fingerprint that can be used to identify individual powder particles.

The AccuTOF-DART™ was recently applied to an unusual analytical problem: finding the cause of oily stains on freshly laundered shirts (Figure 1). No cutting or extraction was required. Stained and unstained regions of the shirt were placed in the DART gas stream and the mass spectra were acquired.  The DART parameters were: helium gas, flow 3-4 LPM, gas heater set to 175 degrees C, positive-ion mode, PEG 600 exact mass reference standard. These conditions did not damage the shirt.

Drug counterfeiting is becoming a serious and widespread public health problem. The number of FDA open investigations into drug counterfeiting rose sharply from 2000 to 2001 and has remained high in recent years. Counterfeit drugs are not only illegal, but dangerous; they may contain little or no actual drug content, or they may contain completely different drugs with potentially toxic consequences. The problem is worldwide; it has been reported that nearly 50% of all anti-malarial drugs in Africa are thought to be counterfeit. Direct Analysis in Real Time (DART™) offers a simple solution to screening for counterfeit drugs. DART can detect the presence or absence of drugs in medicines within seconds by simply placing the pill or medicine in front of the mass spectrometer. In combination with the AccuTOF, DART provides exact masses and accurate isotopic patterns that provide elemental compositions for known and unknown substances.

Gamma hydroxybutyrate (GHB) is a fast-acting central nervous system depressant. Prior to its ban by the FDA in 1990, GHB was sold in bodybuilding formulas. It has been abused as a euphoriant. Because it is colorless and odorless, it can be added to alcoholic drinks of unsuspecting victims. An overdose can result in serious consequences, including respiratory depression and coma. GHB was classified as a Schedule I Controlled Substance in March, 2000. Detection of GHB is problematic. GC/MS and LC/ MS methods are time consuming. A rapid colorimetric assay for GHB has been developed, but this assay suffers from some limitations. For example, ethanol produces the same colorimetric response as GHB. The AccuTOF™ mass spectrometer equipped with Direct Analysis in Real Time (DART™) can rapidly detect GHB anion (C4H7O3 -, m/z 103.0395) on surfaces, in urine, and in ethanol. No solvent extraction, wipes, or chromatography are required. Examples are shown in the figures below.

Poppy seed is a common flavoring ingredient that is known to contain small amounts of opiates. Maximum morphine and codeine concentrations are estimated to be about 33 and 14 micrograms respectively per gram of seed. Consumption of typical amounts of baked goods containing poppy seeds has not been shown to cause any ill effects. However, ingestion of poppy seeds may result in false positives from drug tests. Single poppy seeds from different sources were analyzed independently in two different laboratories by using the DART™/AccuTOF™ combination. The resulting mass spectra were nearly identical.

The widespread presence of illicit drugs on currency is an indication of the extent of the worldwide substance abuse problem. Remarkably, cocaine can be found on virtually all one-dollar bills in the United States — the upper limit for the general background level of cocaine is estimated to be 13 ng per bill. The Direct Analysis in Real Time (DART™) ion source, combined with the AccuTOF™ mass spectrometer can be used to sample drugs on currency within seconds. No sample preparation (extraction, wipes, etc.) or chromatography is required. The bill is placed in front of the DART and the presence of drugs can be detected immediately. Only a small portion of the bill is sampled at any given time. This allows the analyst to view the distribution of drugs on the surface of a bill, and allows the bill to be retained for reexamination at a later time.

The detection of explosives is of vital importance in forensic applications and in preventing criminal or terrorist activity. The analytical detection of explosives on surfaces is normally done by using solvent extractions or wipes and chromatography or chromatography combined with mass spectrometry. This is inefficient because solvent extractions and wipes only result in a partial transfer of material from the surface into the sampling material. Furthermore, the chromatographic analysis can be time-consuming and requires the use of disposable solvents (an environmental concern). The JEOL AccuTOF™ with Direct Analysis in Real Time (DART™) has demonstrated the capability to detect both volatile and involatile explosives on surfaces such as plastic, cloth, concrete, glass, cardboard, metal, and more. No wipes or solvent extractions are required. The method is instantaneous, environmentally friendly, and does not require solvents. An example is shown in this application note.

Analyzing fiber samples has always been difficult by DART®. The problem has been that there is no easy way to hold the fiber in the gas stream without losing it into the vacuum system. A fiber can be secured in the DART gas stream with forceps or other means, but if the DART gas is too hot, the fiber can break off and be lost into the mass spectrometer vacuum system through the atmospheric pressure interface. A thermal desorption/pyrolysis stage (The Biochromato, Inc. “ionRocket™”) designed for use with DART produces highly reproducible thermal desorption profiles that show outgassing, additives, and high-quality pyrolysis DART mass spectra for materials. Because fiber samples placed in the disposable copper sample “pots” are not positioned directly in the DART gas stream, a single fiber can be analyzed without risk of loss into the vacuum system.

DART can be used with a heated gas stream to rapidly pyrolyze and identify low-volatility materials such as adhesives and resins, directly on surfaces. Although these materials are not pure compounds, a library of DART mass spectra can be created and searched to identify materials, and exact mass measurements coupled with accurate isotopic abundances can be used to identify unknown components. Examples are shown here for cured and uncured epoxies and acrylate adhesives on metal and glass.

The explosive peroxide compounds triacetone triperoxide (TATP) and hexamethylenetriperoxide diamine (HMTD) are difficult to detect by conventional mass spectrometry methods. These compounds can be easily detected by the Direct Analysis in Real Time (DART™) ion source.

rss

Other Resources

Walkup NMR
  • See how the Delta NMR software allows users to just "walk up" and start NMR experiments
  • Mass Spec Reference Data
  • View our page of useful molecular references for Mass Spec
  • Tutorials (Mass Spec)
  • Documents on the basics of mass spectrometry
  • Delta NMR software Tutorials
  • Videos on how to use the Delta NMR software
  • No-D NMR
  • Description of No-D NMR and how it can be used to eliminate the need for deuterated solvents
  • Non Uniform Sampling (NUS)
  • Description of how NUS is used to greatly reduce the time needed for running NMR experiments
  • NMR Basics
  • Overview of the Basics of NMR Theory
  • NMR Magnet Destruction
  • See our presentation of the slicing open of a JEOL Delta-GSX 270 MHz NMR Magnet
  • NMR Training
    Basic Operations and System Management for JEOL NMR Users
    Mass Spec Training
    Learn more about spectrometer operation and maintenance, data collection and processing, and advanced MS software operation.
    JEOLink NMR Newsletter
    We publish and send out this NMR newsletter to our customers. They can also be viewed here.
    Mass Media Newsletter
    We publish and send out this Mass Spec newsletter to our customers. They can also be viewed here.